Secutron MR-2900 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Rauchmelder Secutron MR-2900 herunter. intelligent fire alarm control panels mr-2900/mr-2920 Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 8
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Issue 5 Page 1 of 8
INTELLIGENT
FIRE ALARM CONTROL PANELS
Description
The MR-2900 re alarm system control unit is the heart of a
sophisticated microprocessor-based re alarm system. With
the capability of networking, the MR-2900 is ideally suited
for the varied needs of residential, commercial, industrial,
and institutional applications. The MR-2900 provides both
conventional and addressable input circuits. It has the ability
to ‘software’ congure conventional input circuits for alarm or
supervisory function, and operation with contact devices only,
smoke detectors only, or both smoke detectors and contact
devices with the system having the ability to differentiate
between smoke detector and contact device activation.
Addressable input circuits using addressable analog detectors,
monitoring modules, and control modules are available using
addressable input circuit modules.
The MR-2900 has capacity for up to 24 input circuits, four
general purpose Form C relays, and eight polarity reversing
notication appliance (bell) circuits. System operated relays are
available for alarm, trouble, and supervisory indication.
Input circuit modules are available for conventional circuits and
addressable circuits. The MR-2908 and MR-2928 conventional
input circuit modules each have eight Class B circuits which
can be wired for Class A by utilizing two circuits. The MR-2938
conventional input circuit module supports four Style D (Class
A) smoke detector circuits. The MR-2929 addressable input
circuit module supports eight Style 4 (Class B) circuits or four
Style 6 (Class A) circuits.
The rst eight circuits of the MR-2900 control unit are reserved for
conventional circuits while the remaining 16 circuits can be used
for addressable or conventional input circuits in groups of eight.
Features
Listed to UL 864, 9th edition
Sophisticated capabilities yet simple to operate
Conventional and addressable detection circuits
Adjustable sensitivity
Day/night sensitivity
One-person system test capability
Totally software driven
Field programmable via PC
Passcode protection
History log ≈ 1400 events
System alarm, supervisory, and trouble relays
Alarm, supervisory, and trouble LEDs for each zone
Custom labels per zone
Remote alarm and trouble annunciation
Remote detector test capability
LCD supertwist 80 character (4 x 20) backlit display
Sprinkler supervision
Ground fault indication by supervised circuit
Software denable conventional input circuits
Conventional input circuits Style B (Class B) or Style D
(Class A)
Addressable input circuits Style 4 (Class B) or Style 6 (Class A)
Input circuits programmable for N.O. or N.C. contacts
Style Y (Class B) or Style Z (Class A) notication appliance
(bell) circuits
Power limited circuits
DCLR network communication option
Optional integrated strip printer
‘Hot Key’ system controls
Display of real time
Signal silence inhibit
Signal time limit cut-out
Boolean Logic
Supports Acclimate and Pinnacle Smoke Detectors
MR-2920 provides an optional panel mounted printer
MR-2900/MR-2920
Intelligent Addressable Fire Alarm
Control Panels
SECUTRON INC.
Canada 25 Interchange Way, Vaughan (Toronto), Ontario L4K 5W3 Telephone: (905) 695-3545 Fax: (905) 660-4113 • Web Page: www.secutron.com
U.S.A. 4575 Witmer Industrial Estates, Niagara Falls, NY 14305 Telephone: (888) 695-3545 Fax: (888) 660-4113 • E-mail: [email protected]
Catalog Number 1006 • Not to be used for installation purposes.
With the addition of MR-2910 Series network boards, MR- 2900
control units can be networked together to provide additional
input circuits, visual zones, programmable notication appliance
(bell) circuits, and relays. Up to 254 control and annunciator
units can be networked together. The network is a DCLR (Data
Communications Link, Redundant) conguration loop.
Each annunciator can contain up to 576 LEDs (192 zones) for
annunciation purposes, an LCD display for messages, and 16
predened switch inputs for control functions.
MR-2900 Fire Alarm Control Panel
APPROVED
MEA
approved
S6619 352-03-E
7165-1656:100
S6619
Seitenansicht 0
1 2 3 4 5 6 7 8

Inhaltsverzeichnis

Seite 1 - MR-2900/MR-2920

Issue 5 Page 1 of 8INTELLIGENTFIRE ALARM CONTROL PANELSDescriptionThe MR-2900 re alarm system control unit is the heart of a sophisticated microproc

Seite 2 - Main Control Unit

Page 2 of 8 Issue 5System controls consist of 12 system switches (‘Hot Keys’) and a 20 position alphanumeric keypad. The 12 system switc

Seite 3 - Power Supply

Issue 5 Page 3 of 8Field connections are terminated at the terminal board, which in addition to terminal blocks contains a portion of the circuitry fo

Seite 4 - DCLR Loop Layout

Page 4 of 8 Issue 5SECUTRON INC.Catalog Number 1006Not to be used for installation purposes.Enclosure The enclosure for the MR-2900 and the MR-2920 co

Seite 5 - Specications

Issue 5 Page 5 of 8SECUTRON INC.Catalog Number 1006Not to be used for installation purposes.SpecicationsInput Power AC 300 VA nominal; 2.5 A @ 120 VA

Seite 6 - Specications (continued)

Page 6 of 8 Issue 5SECUTRON INC.Catalog Number 1006Not to be used for installation purposes.MR-2920 Panel Mounted Printer, Electrical SpecicationsInp

Seite 7

Issue 5 Page 7 of 8SECUTRON INC.Catalog Number 1006Not to be used for installation purposes.MR-2900 Back Box Dimensions MR-2920 Back Box Dimensions29&

Seite 8 - Ordering Information

Page 8 of 8 Issue 5SECUTRON INC.Catalog Number 1006 • Not to be used for installation purposes.Secutron reserves the right to make changes at any ti

Kommentare zu diesen Handbüchern